• Deutsch
  • Englisch
  • Russisch

Zertifikate
M

  • Deutsch
  • Englisch
  • Russisch

Zertifikate

Erich Ott GmbH & Co. KG
Rüdigerstr. 15
65189 Wiesbaden
Telefon: 0611-761393
Telefax: 0611-711462
E-Mail: info(at)erich-ott.de

Produktion & Empfang
Erich Ott Produktions GmbH
Hasengartenstrasse 44
65189 Wiesbaden
Telefon: 0611 - 9732510

XING Profile

LinkedIn

Ex- B-Pt100, Ex- R-Pt100 HKA UHKATRSC BAltTextEx TBK/ TRK KAEX TF PT 100 LsAltTextEX GHLEx TBK/ TRK KA/ U
Zone 1 in-situ

In our offer for the instruments to be mounted in-situ in Zone 1, we propose:

  • Voltage regulator
  • Capillary tube- temperatur regulator/limiter
  • Pt-100-temperatur regulator/limiter
  • Voltage regulator with the Pt-100 temperature regulator/limiter
  • Heaters
  • Connectors of heating elements
  • Heating elements

General overview

Instruments to be mounted in-situ in Zone 1


Ex- B-Pt100, Ex- R-Pt100
Temperature regulator/limiter
  SIPT AT Voltage regulator with a temperature regulator/limiter
  • ambient temperature range:  -40°C - +50°C
  • regulation range:  0-400°C
  • nominal voltage: 230 V
  • nominal current:  20 mA
  • protection class: IP65
  • cabinet dimensions:  160 x 160 x 90 (140 x 110)
  • three-conductor circuit for assessing the Pt100 sensor probe
  • minimum control with the set-point adjuster
  • the set-point adjuster is sealed
  • triggering device and fault warning relay
  • monitoring of lines of all three conductors
 
  • ambient temperature range:  -30°C - +40°C
  • regulation range:  0 - 400°C
  • nominal voltage: 230 V
  • nominal current: 16 A
  • protection class:  IP65
  • cabinet dimensions: 280 x 160 x 90
  • emergency warning lamp
  • three-conductor circuit for assessing the Pt100 sensor probe
  • minimum control with the set-point adjuster
  • the set-point adjuster is sealed
  • triggering device and fault warning relay probe
  • monitoring of lines of all three conductors
 
Ex TRS...AT Temperature regulator with variable output voltage   Ex TBK/ TRK KA Capillary tube Temperature regulator/limiter  
  • ambient temperature range: -20 C - +40°C
  • regulation range:  5°C - 70°C
  • nominal voltage: 230 V V
  • output voltage: 70-220 V
  • working current: 7 A
  • protection class: IP65 – cabinet dimensions: 160 x 160 x 90 (140 x 110)
  • three-conductor circuit for assessing the Pt100 sensor probe
  • minimum control with the set-point adjuster
  • the set-point adjuster is sealed
  • triggering device and fault warning relay probe
  • monitoring of lines of all three conductors
 
  • ambient temperature range: -40°C - +60°C
  • regulation range:  0-50°C, 0-100°C, 0-300°C
  • nominal voltage:  400 V
  • nominal current: 16 A
  • protection class:  IP65
  • design shape:  (160x75)/(160x160)/(160x260)/ (160x360)
  • capillaries with the VA protective hose
  • testing the single-piece goods with calibration
  • minimum difference between the turn-on temperature and the turn-off one
  • modular type of the structure
 
Ex TBK/ TRK KA/ U Capillary tube – Temperature regulating/limiting module   Ex T. . . AT
Sensors with the triggering function
 
  • ambient temperature range: -40° C - +60° C
  • regulation range:  0 - 50° C, 0 - 100° C, 0 - 300° C
  • nominal voltage:  400 V
  • nominal current: 16 A
  • protection class:  IP65
  • design shape:  91 x 60 mm
  • testing a single product with taring
  • minimum difference between the turn-on temperature and the turn-off one
  • modular type of the structure
  • repairable module
 
  • ambient temperature range: -40°C - +180°C
  • regulation range:  0-400°C
  • nominal voltage:  230 V
  • nominal current:  10 A
  • protection class: IP66
  • design shape: 95 x 40 x 35 for the limiter
    74 x 37 x 28 design shape: 95 x 40 x 35 for the limiter, 74 x 37 x 28 for the regulator and protective facility
  • integrated sensor
  • integrated reset limiter
 
Ex TF . . . 100 Ks
Temperature sensor
  Ex TF . . . 100 L
Temperature sensor
 
  • ambient temperature range: -40°C to +200°C
  • measurement range: -40°C - +400°C
  • nominal voltage of the Ua series: 24V
  • nominal voltage:  2.3 V
  • nominal measurable current: 1-10 mA
  • protection class: IP65
  • design shape:  74 X 22 x 22 mm
  • sensor probe: 5 x 50 mm
  • available as an intrinsically safe sensor
  • aluminium or steel case
 
  • ambient temperature range:  -40°C to +80°C
  • measurement range: -40°C - +200°C
  • nominal voltage of the Ua series: 24 V
  • nominal voltage: 1,8 V
  • nominal measurable current: 1-10 mA
  • protection class: IP65
  • design shape: 74 X 22 x 22 mm
  • available as an intrinsically safe sensor
  • aluminium or steel case
 
Ex HKA / U AT
Heating element
  Ex HKA ... / 100 AT
Heating element with the temperature regulator/limiter
 
  • ambient temperature range: -40°C - +130°C
  • maximum heating power: 370 W
  • nominal voltage: 230 V
  • nominal current: 6 A
  • protection class: IP65
  • design shape: 210 x 273 x 50
  • optimized – reflection through black varnish and dense heating ribs
 
  • ambient temperature range:  -40°C - +80°C
  • maximum heating power: 370 W
  • nominal voltage: 230 V
  • nominal current: 1,4 - 4,4 A
  • nominal current of the monitoring instrument: 6 A
  • protection class: IP65
  • limiter 112°C
  • design shape: 210 x 273 x 50
  • optimized – reflection through black varnish and dense heating ribs
  • the regulator and limiter are integrated in the switching unit
  • thermostat for alarm
 
Ex GH ... ALAT
Connecting accessories
  Ex GHL ALAT
Connecting accessories
 
 

  • ambient temperature range: -40°C to +80°C
  • heating power: 80W/m nominal voltage: 230 V
  • nominal current: 16 A/ 32 A
  • protection class: IP65
  • design shape: 100 x 32 mm
  • pre-terminated filling compound (optional)
  • screw and terminal fastening with nuts M24
  • for heating appliances with mineral insulation and  PFTE
  • available also as a coupling for connectors 1 to 1
 
Ex SIPT L  Protective temperature limiter with the power regulator    
  • ambient temperature range: -40°C - +55°C
  • regulation range: 0 - 500°C
  • nominal voltage: 230 V
  • nominal current: 30 A
  • voltage range: 30 V - 400V
  • protection class: IP65
  • cabinet dimensions: 280 x 230 x 165
  • digital temperature readings, actual values of the regulator and limiter
  • voltage and current readings
  • setting the parameters through the button control
  • message on the faults of the regulator and limiter
  • switching relay and fault warning relay
  • phase control/operation on high tide
  • monitoring of all three conductors of sensors
   
 

Um unsere Webseite für Sie optimal zu gestalten und fortlaufend verbessern zu können, verwenden wir Cookies. Durch die weitere Nutzung der Webseite stimmen Sie der Verwendung von Cookies zu. Weitere Informationen zu Cookies erhalten Sie in unserer Datenschutzerklärung